Ventilator Weaning Difficulties in ICU: A Study on VAP Patients with Post-Tracheostomy, Thoracic Trauma, and Thoracic Spinal Cord Injury

Authors

  • Virgiana Piesesha Faculty of Nursing, University of Jember, Indonesia

DOI:

https://doi.org/10.58545/jkmi.v4i1.154

Abstract

Ventilator weaning failure is an inability to adapt to reduced mechanical ventilator assistance, which can slow down and prolong the weaning process. Ventilator weaning failure is characterized by increased respiratory rate, use of respiratory muscles, gasping breath, out-of-synchronization efforts to assist breathing and ventilator support, shallow breathing, agitation, and abnormal blood gas arteries. Ventilator weaning failure is an inability to spontaneous breathing trial (SBT), re-intubation, and assisted ventilation after extubation or death within 48 hours after extubation. Weaning process failure factors are divided into non-ventilator and ventilator factors. Ventilator factors include poor patient conditions, long-term use of ventilators, and abnormal blood gas analysis (BGA). Meanwhile, the ventilator factor is related to the condition of the patient's lungs that have suffered severe damage or barotrauma and excessive tidal volume pressure. This study analyzes ventilator weaning failure in patients with Ventilator-Associated Pneumonia (VAP), Post Thoracic Trauma, and Post Spinal Cord Injury in Thoracic 10-12 at the intensive care unit. This research method is based on case reports by compiling comprehensive nursing care. The results of the analysis of ventilator weaning failure in this patient are related to the worsening of the patient's condition, complex thoracic trauma, prolonged use of mechanical ventilators causing ventilator-associated pneumonia (VAP), and respiratory acidosis.

Keywords:

Ventilator Weaning Difficulties, Post-Tracheostomy, Thoracic Trauma, Spinal Cord Injury, Ventilator-associated Pneumonia

Downloads

Download data is not yet available.

References

Amri, U., Syarif, H., & Aklima. (2022). Management of Acute Respiratory Failure Et Cause Chronic Kidney Disease in the Intensive Care Unit: A Case Study. JIM FKEP. 1(3): 1–7. https://jim.usk.ac.id/FKep/article/view/21018

Cecep, Maryana, & Faizal, M. (2023). Nurses' experiences in the ventilator weaning process in the ICU. Journal of Professional Nursing Research. 5(2): 559–572. https://doi.org/10.37287/jppp.v5i2.1514

Coary, R., Skerritt, C., Carey, A., Rudd, S., & Shipway, D. (2020). New Horizons In Rib Fracture Management In The Older Adult. Age And Aging. 49(2):161–167. https://doi.org/10.1093/ageing/afz157

Dongol, S., Kayastha, G., Maharjan, N., Pyatha, S., K C, R., Thwaites, L., … Karkey, A. (2021). Epidemiology, etiology, and diagnosis of health care acquired pneumonia including ventilator-associated pneumonia in Nepal. PloS One, 16(11), e0259634. https://doi.org/10.1371/journal.pone.0259634

Febyan, F., & Lardo, S. (2020). Concept on Series Pathogenesis of Ventilator-Associated- Pneumonia in Intensive Care Unit. Journal of the Indonesian Medical Association, 68(12), 492-500. https://doi.org/10.47830/jinma-vol.68.12-2018-209

Kao, H. H., Peng, C. K., Sheu, C. C., Lin, Y. C., Chan, M. C., Wang, S. H., Chen, C. M., Shen, Y. C., Zheng, Z. R., Lin, Y. T., Hsu, H. S., Feng, J. Y., Yang, K. Y., & T-CARE (Taiwan Critical Care and Infection) Group (2023). Mortality and ventilator dependence in critically ill patients with ventilator-associated pneumonia caused by carbapenem-resistant Acinetobacter baumannii. Journal of microbiology, immunology, and infection = Wei mian yu gan ran za zhi, 56(4), 822–832. https://doi.org/10.1016/j.jmii.2023.04.004

Kyriakoudi, A., Rovina, N., Koltsida, O., Kostakou, E., Konstantelou, E., Kardara, M., Kompoti, M., Palamidas, A., Kaltsakas, G., & Koutsoukou, A. (2021). Weaning Failure in Critically Ill Patients Is Related to the Persistence of Sepsis Inflammation. Diagnostics (Basel, Switzerland), 12(1), 92. https://doi.org/10.3390/diagnostics12010092

Latipah, S. (2019). The Relationship between Pneumonia Client Characteristics and the Success of Mechanical Ventilation Weaning at X Hospital Tangerang. Indonesian Nursing Scientific Journal. 2(2):140–148. https://jurnal.umt.ac.id/index.php/jik/article/view/5884

May, L., Hillermann, C., & Patil, S. (2016). Rib Fracture Management. BJA Education. 16(1):26–32. https://doi.org/10.1093/bjaceaccp/mkv011

Octavia, A. C., Setyaningtyas, A., & Edwar, P. P. M. (2020). Electrolytes Profile of Critically Ill Patients Admitted To Pediatric Intensive Care Unit (PICU) Dr. Soetomo General Hospital. Indonesian Journal of Anesthesiology and Reanimation, 2(1), 1–7. https://doi.org/10.20473/ijar.V2I12020.1-7

Peek, J., Beks, R. B., Kremo, V., van Veelen, N., Leiser, A., Houwert, R. M., Link, B. C., Knobe, M., Babst, R. H., & Beeres, F. J. P. (2021). The evaluation of pulmonary function after rib fixation for multiple rib fractures and flail chest: a retrospective study and systematic review of the current evidence. European journal of trauma and emergency surgery: official publication of the European Trauma Society, 47(4), 1105–1114. https://doi.org/10.1007/s00068-019-01274-3

Spinelli, E., Mauri, T., Beitler, J. R., Pesenti, A., & Brodie, D. (2020). Respiratory drive in the acute respiratory distress syndrome: pathophysiology, monitoring, and therapeutic interventions. Intensive care medicine, 46(4), 606–618. https://doi.org/10.1007/s00134-020-05942-6

Vallecoccia, M. S., Dominedò, C., Cutuli, S. L., Martin-Loeches, I., Torres, A., & De Pascale, G. (2020). Is ventilated hospital-acquired pneumonia a worse entity than ventilator-associated pneumonia?. European respiratory review: an official journal of the European Respiratory Society, 29(157), 200023. https://doi.org/10.1183/16000617.0023-2020

Downloads

Published

27-02-2025

How to Cite

Piesesha, V. (2025). Ventilator Weaning Difficulties in ICU: A Study on VAP Patients with Post-Tracheostomy, Thoracic Trauma, and Thoracic Spinal Cord Injury. Jurnal Kegawatdaruratan Medis Indonesia, 4(1), 1–13. https://doi.org/10.58545/jkmi.v4i1.154

Issue

Section

Articles

PlumX Metrics